ChemBK
  • Home
  • Product Category


TETRAETHYLLEAD

  1. Home
  2. Product Category
  3. Organic raw materials
  4. TETRAETHYLLEAD

TETRAETHYLLEAD - Names and Identifiers

Name TETRAETHYLLEAD
Synonyms TETRAETHYLLEAD
leadtetraethyl
leadtetraethide
Lead tetraethyl
lead,tetraethyl-
Czteroetylek olowiu
czteroetylekolowiu
czteroetylekolowiu(polish)
CAS 78-00-2
EINECS 201-075-4

TETRAETHYLLEAD - Physico-chemical Properties

Molecular FormulaC8H20Pb
Molar Mass323.44
Density1.653 g/mL at 25 °C(lit.)
Melting Point−136 °C(lit.)
Boling Point84-85 °C15 mm Hg(lit.)
Flash Point84 °F
Water Solubility不溶于水、稀酸、稀碱液,溶于多数有机溶剂。
Refractive Index0
Physical and Chemical PropertiesColorless oily liquid, odor.

TETRAETHYLLEAD - Determination of tetraethyl lead by inductively coupled plasma mass spectrometry with dual gas path calibration-solid phase microextraction

From HowNet

Author:

Li Ming , Li Airong , Shuai Qin , Hu Shenghong

Summary:

a new method for SPME-ICP-MS determination of metal organic compounds was established by using a self-designed double gas path thermal analysis interface unit of solid phase microextraction,SPME) combined with inductively coupled plasma mass spectrometry (inductively coupled mass spectrometry,ICP-MS). The dual gas path thermal analysis interface unit enables on-line thermal analysis of the sample and synchronously enters the plasma ionization with the pneumatically atomized internal standard solution aerosol. The linear range of the method is 0.05~100 ng/mL, the relative standard deviation is 1.3% ~ 6.6%(n = 5), and the detection limit is 2 pg/mL. The established method has been applied to the determination of tetraethyl lead in synthetic water samples, and the recovery rate of standard addition is 93% ~ 105%.

keywords:

solid phase microextraction inductively coupled plasma mass spectrometry interface technology tetraethyl lead

DOI:

10.3969/j.issn.1000-0720.2007.06.029

cited:

59

Year:

2007

Last Update:2024-01-02 23:10:35

TETRAETHYLLEAD - Determination of trace tetraethyl lead in water by gas chromatography-mass spectrometry

From VIP Journal Professional Edition

Author:

Yang Lili, Wang Meifei, Li Juan, Hu Enyu

Summary:

an analytical method for the determination of trace tetraethyl lead in water by gas chromatography-mass spectrometry (GC-MS) has been established. Tetraethyl lead in water samples was extracted with n-hexane, and the isotope internal standard naphthalene-d8 was added after the extraction solution was concentrated. The detection limit of tetraethyl lead in 200mL water samples was 0.04 μg/L by GC-MS selective ion method (SIM). The addition recovery rate is 92.2% ~ 103% with good accuracy. The relative standard deviation of 5 parallel determinations is 4.4% ~ 13.3%. The results show that the method is simple, rapid, accurate and practical, and can be used for the determination of trace tetraethyl lead in water.

keywords:

gas chromatography-mass spectrometry, tetraethyl lead, water

DOI:

10.3724/SP.J.1123.2010.00993

cited:

30

Year:

2010

Last Update:2023-08-16 22:09:50

TETRAETHYLLEAD - Dynamic observation on the effect of tetraethyl lead on the health of workers

Author:

Wang Hongbo ,< a href = "https://xueshu.baidu.com/s?wd=author: (Feng Yongkang) & tn = SE_baiduxueshu_c1gjeupa & ie = utf-8 & SC _f_para = SC _hilight = person" target = "_blank"> Feng Yongkang ,< a href = "https://xueshu.baidu.com/s?wd=author: (Hu Gang) & tn = SE_baiduxueshu_c1gjeupa & ie = utf-8 & SC _f_para = SC _hilight = person" target = "_blank"> Hu Gang , Zhang Hua , Chang hong , Zhang Zhenyu

Summary:

This paper reports a dynamic observation of the 7-year health effects of tetraethyl lead on 30 operators. The results showed that the syndrome of mental failure and autonomic dysfunction were linearly related to the concentration of tetraethyl lead in the air of the working environment. It is suggested that these two diseases can be gradually recovered with the decrease of tetraethyl lead concentration in the air of working environment. Whether urinary lead is an ideal indicator for evaluating exposure to tetraethyl lead is worth exploring.

keywords:

tetraethyl lead dynamic observation

DOI:

CNKI:SUN:LDYX. 0.1993-03-001

cited:

3

Year:

1993

Last Update:2023-08-16 22:09:50